data.gift
  • Datasets

http://cyfun.data.gift/data/requirement_PR_IR_02_1

http://cyfun.data.gift/data/requirement_PR_IR_02_1
Concept

  • http://cyfun.data.gift/data/CyFun2025

    • External link
    • Internal link
  • http://cyfun.data.gift/data/CyFun2025_delta_BASIC_to_IMPORTANT

    • External link
    • Internal link
  • http://cyfun.data.gift/data/CyFun2025_IMPORTANT

    • External link
    • Internal link
  • http://cyfun.data.gift/data/CyFun2025_ESSENTIAL

    • External link
    • Internal link

  • http://cyfun.data.gift/data/subcategory_PR.IR-02

    • External link
    • Internal link

Properties and relations

Direct links from the subject.

Property Value

type

The subject is an instance of a class.

  • External link
  • Internal link

http://cyfun.data.gift/ontology#Requirement

  • External link
  • Internal link

type

The subject is an instance of a class.

  • External link
  • Internal link

Concept

An idea or notion; a unit of thought.

  • External link
  • Internal link

label

A human-readable name for the subject.

  • External link
  • Internal link

PR.IR-02.1: The organisation shall define, implement and maintain policies and procedures related to emergency and safety systems, fire protection systems and environmental controls for its critical systems.

http://cyfun.data.gift/ontology#requirementId

  • External link
  • Internal link

PR.IR-02.1

http://cyfun.data.gift/ontology#foundIn

  • External link
  • Internal link

http://cyfun.data.gift/data/loc_CyFun2025_Booklet_IMPORTANT_E_p93

  • External link
  • Internal link

http://cyfun.data.gift/ontology#foundIn

  • External link
  • Internal link

http://cyfun.data.gift/data/loc_CyFun2025_Booklet_ESSENTIAL_E_p140

  • External link
  • Internal link

has broader

Relates a concept to a concept that is more general in meaning.

  • External link
  • Internal link

http://cyfun.data.gift/data/subcategory_PR.IR-02

  • External link
  • Internal link

note

A general note, for any purpose.

  • External link
  • Internal link

The goal of this control is to protect critical systems from environmental hazards and emergencies that could disrupt operations, damage equipment, or endanger safety — especially in OT environments where physical conditions directly impact system availability and human safety. To achieve this goal, the organisation should: - Conduct risk assessments of all locations housing critical systems to identifyenvironmental and emergency risks. - Define policies and procedures for fire protection, emergency response, and environmental controls. - Install monitoring systems such as temperature, humidity, smoke, and water leak sensors, with alerts for abnormal conditions. - Implement fire protection measures including appropriate suppression systems (e.g. gas-based for data centres), alarms, detectors, and extinguishers. - Inspect and maintain fire safety and environmental systems regularly, including HVAC and emergency lighting. - Include environmental protection requirements in third-party contracts, and request evidence of com- pliance and maintenance. - Train staff on emergency procedures and conduct evacuation and fire response drills at least annually.

note

A general note, for any purpose.

  • External link
  • Internal link

The goal of this control is to protect critical systems from environmental hazards and emergencies that could disrupt operations, damage equipment, or endanger safety — especially in OT environments where physical conditions directly impact system availability and human safety. To achieve this goal, the organisation should: • Conduct risk assessments of all locations housing critical systems to identifyenvironmental and emergency risks. • Define policies and procedures for fire protection, emergency response, and environmental controls. • Install monitoring systems such as temperature, humidity, smoke, and water leak sensors, with alerts for abnormal conditions. • Implement fire protection measures including appropriate suppression systems (e.g. gas-based for data centres), alarms, detectors, and extinguishers. • Inspect and maintain fire safety and environmental systems regularly, including HVAC and emergency lighting. • Include environmental protection requirements in third-party contracts, and request evidence of com- pliance and maintenance. • Train staff on emergency procedures and conduct evacuation and fire response drills at least annually.

note

A general note, for any purpose.

  • External link
  • Internal link

<div><p>The goal of this control is to protect critical systems from environmental hazards and emergencies that could disrupt operations, damage equipment, or endanger safety — especially in OT environments where physical conditions directly impact system availability and human safety. To achieve this goal, the organisation should:</p><ul><li>Conduct risk assessments of all locations housing critical systems to identifyenvironmental and emergency risks.</li><li>Define policies and procedures for fire protection, emergency response, and environmental controls.</li><li>Install monitoring systems such as temperature, humidity, smoke, and water leak sensors, with alerts for abnormal conditions.</li><li>Implement fire protection measures including appropriate suppression systems (e.g. gas-based for data centres), alarms, detectors, and extinguishers.</li><li>Inspect and maintain fire safety and environmental systems regularly, including HVAC and emergency lighting.</li><li>Include environmental protection requirements in third-party contracts, and request evidence of com- pliance and maintenance.</li><li>Train staff on emergency procedures and conduct evacuation and fire response drills at least annually.</li></ul></div>

note

A general note, for any purpose.

  • External link
  • Internal link

The goal of this control is to protect critical systems from environmental hazards and emergencies that could disrupt operations, damage equipment, or endanger safety — especially in OT environments where physical conditions directly impact system availability and human safety. To achieve this goal, the organisation should: - Conduct risk assessments of all locations housing critical systems to identifyenvironmental and emergency risks. - Define policies and procedures for fire protection, emergency response, and environmental controls. - Install monitoring systems such as temperature, humidity, smoke, and water leak sensors, with alerts for abnormal conditions. - Implement fire protection measures including appropriate suppression systems (e.g. gas-based for data centres), alarms, detectors, and extinguishers. - Inspect and maintain fire safety and environmental systems regularly, including HVAC and emergency lighting. - Include environmental protection requirements in third-party contracts, and request evidence of com- pliance and maintenance. - Train staff on emergency procedures and conduct evacuation and fire response drills at least annually.

notation

A notation, also known as classification code, is a string of characters such as "T58.5" or "303.4833" used to uniquely identify a concept within the scope of a given concept scheme.

  • External link
  • Internal link

PR.IR-02.1

alternative label

skos:prefLabel, skos:altLabel and skos:hiddenLabel are pairwise disjoint properties.

  • External link
  • Internal link

Environmental and safety controls

preferred label

A resource has no more than one value of skos:prefLabel per language tag, and no more than one value of skos:prefLabel without language tag.

  • External link
  • Internal link

The organisation shall define, implement and maintain policies and procedures related to emergency and safety systems, fire protection systems and environmental controls for its critical systems.

is in scheme

Relates a resource (for example a concept) to a concept scheme in which it is included.

  • External link
  • Internal link

http://cyfun.data.gift/data/CyFun2025

  • External link
  • Internal link

is in scheme

Relates a resource (for example a concept) to a concept scheme in which it is included.

  • External link
  • Internal link

http://cyfun.data.gift/data/CyFun2025_delta_BASIC_to_IMPORTANT

  • External link
  • Internal link

is in scheme

Relates a resource (for example a concept) to a concept scheme in which it is included.

  • External link
  • Internal link

http://cyfun.data.gift/data/CyFun2025_IMPORTANT

  • External link
  • Internal link

is in scheme

Relates a resource (for example a concept) to a concept scheme in which it is included.

  • External link
  • Internal link

http://cyfun.data.gift/data/CyFun2025_ESSENTIAL

  • External link
  • Internal link

http://cyfun.data.gift/ontology#level

  • External link
  • Internal link

http://cyfun.data.gift/data/level_IMPORTANT

  • External link
  • Internal link

triple count

The number of triples associated with the subject.

  • External link
  • Internal link

19

in dataset

Specifies the dataset the subject is part of.

  • External link
  • Internal link

http://data.gift/d/datasets/69E8863AA6CE46D9ACD13109

  • External link
  • Internal link

Resultaten 1 - 21 of 21

References

Inverse links to the subject.

Property Subject

http://cyfun.data.gift/ontology#hasRequirement

  • External link
  • Internal link

http://cyfun.data.gift/data/subcategory_PR.IR-02

  • External link
  • Internal link

has narrower

Relates a concept to a concept that is more specific in meaning.

  • External link
  • Internal link

http://cyfun.data.gift/data/subcategory_PR.IR-02

  • External link
  • Internal link

Resultaten 1 - 1 of 1